A two-stage temperature lift bridges large temperature differences in high-temperature heat pumps. This makes it possible to raise low-temperature waste heat of around 30 to 40°C to the high process temperatures often required in the food, textile or pharmaceutical industries.
How does a heat pump work?
A heat pump extracts heat at low temperatures from its surroundings and uses electricity to raise it to a higher, usable temperature. Conventional heat pumps for single-family homes, district heating networks or industrial sites rely on thermal environmental energy, electrical energy and refrigerants to reach the desired output temperature.
Heat energy is drawn from a heat source, such as ambient air, water or ground, and transferred to a heat sink through a closed cycle in which the refrigerant continuously changes state. The process follows four steps:
- Heat absorption: Liquid refrigerant flows through an evaporator positioned where heat can be absorbed from the environment. The refrigerant absorbs this heat and vaporizes.
- Compression: The now gaseous refrigerant passes through a compressor, which significantly raises its temperature.
- Heat dissipation: The hot, gaseous refrigerant moves to a condenser, where it transfers heat to the heat sink through a heat exchanger. The refrigerant cools and returns to a liquid state.
- Expansion: The liquid refrigerant flows through an expansion valve, which lowers the pressure and cools the refrigerant further so it can absorb new heat.
This operating principle applies to high-temperature heat pumps used in industrial settings. In these systems, a two-stage temperature increase, nown as a two-stage temperature lift, is often required.
What are a heat source and a heat sink?
The heat source supplies the thermal energy that drives the system. In heat pumps used for heating buildings, the heat source is typically ambient air or the ground. In industrial applications, it is usually the residual and process heat generated by industrial processes, as is the case with VQ180, (formerly branded ThermBooster™).
The heat sink is the point where the generated heat is delivered to its destination. The efficiency and effectiveness of a high-temperature heat pump system depends heavily on the properties of both the heat source and the heat sink.
Building the temperature difference between the heat source and the heat sink is known as the temperature lift. Due to their design, single-stage heat pumps can only achieve a temperature lift within a certain range, typically bridging a difference of around 60°C.
Kelvin or degrees Celsius: In science and technology, temperature difference (or temperature delta) is usually expressed in Kelvin (K). The difference between two temperature values in Kelvin and degrees Celsius (°C) is numerically the same, so a temperature difference of 60 Kelvin equals a temperature difference of 60°C.
Why can two-stage heat pumps overcome single-stage limitations?
A two-stage temperature lift allows industrial heat pumps to raise low-temperature residual heat of around 30 to 40°C to the 160 to 165°C range required by many industrial processes, without the unfavorable coefficient of performance (COP) often assumed to come with pushing past single-stage limits.
It is often wrongly assumed that overcoming the limits of single-stage heat pumps always comes at the cost of an unfavorable COP. This assumption is one reason low-temperature waste heat of 30 to 40°C is frequently left unused: single-stage heat pumps are generally though capable of heating it only to around 90 to 100°C, which is too low for most industrial processes. As a result, valuable waste heat generated during manufacturing, processing and refining is often wasted rather than recovered.
To use this heat effectively, industrial heat pumps need a larger temperature lift. This is where the Vilter VQ180, with its two-stage temperature range, comes in.
Efficiency and COP: Efficiency describes the ratio between the energy supplied and the work performed. A system that takes in 100 units of energy and produces 70 units of work has an efficiency of 0.7 or 70%. The COP describes the ratio between the energy input and the heat or cold output. Unlike efficiency, the COP of a heat pump can exceed 1 or 100%, because heat pumps draw on ambient heat. A high-temperature heat pump can achieve a COP of 2.5 and higher.
How does the two-stage temperature work?
In a two-stage, cascaded heat pump process, two separate refrigerant circuits and two compressors work together to achieve a higher temperature lift than a single compression cycle can deliver.
In conventional heat pump systems, a single compression cycle raises the refrigerant temperature from the heat source to the desired output temperature at the heat sink. The design limits of the compressor, combined with the properties of the refrigerant used, cap the maximum temperature lift achievable this way.
To overcome this limit, high-temperature heat pumps often use a two-stage, cascaded process. Two refrigerant circuits, each using a different refrigerant optimized for its own temperature and pressure range, work with two compressors. The condenser of the first circuit also serves as the evaporator of the second circuit. This setup allows compressors, valves and refrigerants to be optimized for very different system requirements, a prerequisite for safe, reliable and efficient operation.
Optimized refrigerants: Refrigerants differ from each other in their thermodynamic properties, which makes certain refrigerants particularly suited to certain temperature ranges. These differences lie primarily, though not exclusively, in the evaporation curve: the temperature at which a refrigerant evaporates at a given pressure.
By splitting the system into two coordinated circuits, the heat pump achieves higher output temperatures and a significantly greater temperature lift than a single refrigerant circuit allows.
What are the advantages of a two-stage temperature lift?
A two-stage temperature lift in high-temperature heat pumps offers two key advantages:
- Extended temperature range: Higher output temperatures become achievable than with single-stage compression. This extended temperature range increases the versatility of the heat pump and opens new areas of application, allowing waste heat of just 30 to 40°C to be raised to over 160°C and used effectively.
- Improved performance: The optimized compression process in both stages improves the performance and reliability of the entire heat pump system, resulting in better process control, productivity and overall operating efficiency for industrial applications.
Where can two-stage high-temperature heat pumps be applied?
A two-stage temperature lift offers particular advantages when the required temperature lift or output temperature exceeds what single-stage compression can achieve, typically when the desired temperature lift is above 60°C.
Application example : Copeland (formerly SPH) and Felix Schoeller
As part of the EU-funded Push2Heat project, Copeland (formerly SPH) supplied the high-temperature heat pump VQ180 (formerly ThermBooster™), featuring a two-stage temperature lift to paper manufacturer Felix Schoeller.
Felix Schoeller generates low-pressure steam at around 2 bar(a), used to dry the paper produced. Heat recovered from the paper machine at around 45°C, which would normally be lost, is used to operate the VQ180. Because the next step requires a relatively high temperature lift, the heat pump operates in two stages.
Housed in containers, the VQ180 will save Felix Schoeller considerable amounts of CO2 emissions and unnecessary energy costs every year.
What does the two-stage temperature lift mean for industrial heat recovery?
The two-stage temperature lift gives high-temperature heat pumps the ability to achieve a significantly greater temperature lift and higher output temperatures than single-stage systems allow.
By splitting the temperature lift into two stages, heat pump systems such as the VQ180 can meet the demanding thermal requirements of various industrial processes effectively and sustainably, even when the available waste heat measures only 30 to 40°C.
By the way: For more on how high-temperature heat pumps supply process steam, see the related article: <Full steam ahead: High-temperature heat pumps provide process steam>
FAQs
What temperature lift can a single-stage heat pump achieve?
A single-stage heat pump can typically bridge a temperature difference of around 60 degrees Celsius due to the design limits of its compressor and refrigerant.
Why is low-temperature waste heat often left unused?
Low-temperature waste heat of 30-40°C is often assumed to be heatable only to around 90-100°C in single-stage heat pumps, a range too low for most industrial processes, so it frequently goes unused even though it can be recovered effectively with a two-stage system.
What output temperature can the Vilter VQ180 reach?
Using a two-stage temperature lift, the Vilter VQ180 can raise waste heat from around 30-40°C to temperatures of approximately 160-165°C, meeting the requirements of many industrial processes.
How many refrigerant circuits does a two-stage heat pump use?
A two-stage, cascaded heat pump process uses two refrigerant circuits and two compressors, each optimized for the specific temperatures and pressures within its stage.
Expert guidance on the VQ180
Wondering how the VQ180 fits into a specific application? Copeland experts work directly with customers to develop solutions.