Person wearing an apron using a tablet in front of refrigerated grocery shelves stocked with produce and food items, with a prominent “CO₂” text overlay representing carbon emissions, sustainability, or environmental monitoring.

CO₂ transcritical booster system integration makes for “flawless” start-up

Andre Patenaude

A well-integrated CO₂ transcritical booster system can deliver a smooth, low-hassle commissioning process even on a first-time installation. 

 

Refrigeration journeyman Don Cole recounted the seamless commissioning of Copeland CO₂ solution in Zero Zone system, describing a start-up free of the typical hiccups associated with new equipment.

 

 

Retail Shopper Selecting Products from Refrigerated Display

Why are CO₂ booster refrigeration systems becoming the standard in California?

Compared to other states, California is ahead of the curve in adopting low-global warming potential (GWP) refrigerants. According to Don Cole, director of training and a journeyman refrigeration technician at Arctic Cooling Systems in Chino, California, CO₂ booster refrigeration systems have quickly become the dominant architecture in new retail stores. 

 

“Almost every grocery chain I can think of is installing CO₂ booster systems,” he said. 

 

 

What does commissioning a CO₂ transcritical booster system involve? 

Commissioning a CO₂ transcritical system is somewhat of an art form and can be challenging. During the start-up process, technicians typically follow a sequence of many steps, which include these key benchmarks: 

 

  • Staging medium (MT) and low (LT) temperature compressors 
  • Ramping up to full speed or capacity 
  • Regulating system pressures in the gas cooler, flash tank, high-pressure valves (HPVs) and bypass gas valves (BGVs) 
  • Minimizing oil carry-over, especially during the supercritical mode of operation 

 

As someone who has embraced the initial emergence of CO₂ refrigeration in California, Cole has worked with a share of CO2 booster systems. For the past five years, he has helped to install, start up and commission CO2 systems from various equipment and component manufacturers. He now leverages nearly three decades of refrigeration experience to educate associates of the Arctic Cooling System organization and serves as a certified trainer at the local United Association of Journeymen and Apprentices of the Plumbing and Pipefitting Industry of the United States and Canada (UA) 250 HVACR branch. 

 

“It’s a passion. I am a believer in CO₂ refrigeration,” he said. 

 

 

How did an integrated CO₂ refrigeration solution reduce start-up challenges?

At a new installation in 2023, Cole led a contractor team through the start-up process, using a Zero Zone CO₂ booster system with a full-Copeland solution of compression, controls, valves and associated components. Despite his experience, Cole explained that every installation comes with potential snags.

 

“You have to understand that with a start-up, the system’s never run before. You have to test every aspect 100%, and there are always some hiccups,” he said. 

 

Cole and his team quickly discovered that the Zero Zone CO₂ booster system powered by Copeland significantly reduced these hiccups. 

 

“Everything just meshed and worked perfectly together,” he said, referring to how the coordination of each component contributed to a nearly stress-free installation.

 

 

Zero Zone CO2 booster system

What makes the integrated system design of this CO₂ transcritical booster system effective?

The Zero Zone CO₂ booster system featured a seamlessly integrated full-Copeland solution, including the following compression and controls:

 

  • Copeland 4MTLS28ME transcritical CO₂ semi-hermetic compressors
  • Copeland ZO and ZOD subcritical CO₂ scroll compressors 
  • Copeland EVH series variable frequency drive (VFD) , paired with lead transcritical compressor
  • Copeland compressor electronics technology
  • Copeland CV4 stepper motor-driven HPV and BGV
  • Copeland E2 supervisory control
  • Copeland CC200 and XM679 case controllers 

 

To regulate system pressures and ensure stable operation, CO₂ booster systems rely on a robust electronic controls ecosystem. The Zero Zone CO₂ system was designed with Copeland compressor, rack, case and valve controls, which enabled holistic system connectivity and communication. This all-Copeland solution was critical for facilitating each phase of the start-up process and managing normal operation by:

 

  • Controlling variable-speed fans
  • Modulating HPVs and BGVs
  • Regulating consistent flash tank pressures
  • Coordinating smooth compressor staging

 

Cole explained how this configuration played a key role in bringing the system into equilibrium during start-up. 

 

“The CV4 high-pressure valve ran flawlessly,” he said, noting that communication with Copeland compressor electronics technology provided further assurance.

 

Copeland’s onboard compressor electronics technology gave Cole’s contractor team additional tools to monitor performance data. “There’s so much data that it makes troubleshooting easy,” he said, noting that his team had no issues with any of the compressors during this start-up. 

 

Should any issues arise, the system features built-in safety measures to help protect compressors from harm or failure and preserve end users’ system investments.

 

 

How did the system perform during compressor staging and vibration testing?

When it came time to get compressor racks up and running, Cole recounted how the operation of Copeland compressors and VFDs surpassed anything he’d previously worked with, particularly in terms of quiet sound, low vibration levels and high performance.

 

“It was so quiet that I was physically a foot and a half away, and I couldn’t hear it,” he said.

 

His next course of action was to test the vibration levels as compressors ramped up to full speed using the EVH drive. He shared that this step typically requires his teams to skip hertz increments as they bring racks online and up to speed. Dealing with this issue can be a major source of frustration for technicians during system start-up and potentially put the system at risk of damage.

 

“I’m usually the one that has to make sure all compressors are rotating the correct way and figure out if we’re fighting opposing forces,” he said. 

 

But with the Copeland compression and drive combination, Cole said these concerns were all but eliminated.

 

“Vibration levels were non-existent all the way from 25 to 60 Hz, which we had never seen before,” he said. “I was giggling like a kid in a candy store with a $20 bill.”

 

 

How did the system manage oil carry-over in supercritical mode?

Because the installation took place in the warm Southern California climate, the CO₂ booster system was designed and expected to run in supercritical mode much of the time. Typically, this can cause a rise in oil carry-over rates that can lead to poor lubrication and an increased risk of compressor damage. 

 

Cole explained that from his calculations, it appeared that the oil carry-over rate was very low in the all-Copeland system, saying, “There was nowhere near the oil we typically see moving through a system.” 

 

As with any start-up process, Cole said his team needed some help familiarizing themselves with the new equipment. At one point during the installation, they needed assistance setting the discharge temperatures on the Copeland compressor electronics module. After a quick phone call to a Copeland solutions architect, Cole was directed to the correct application engineering bulletin and the exact page number with programming instructions.

 

“Copeland support has been absolutely unbelievable,” he said.

 

 

Copeland Building

Why is this considered a model CO₂ refrigeration solution?

 

After a successful start-up process, Cole said that the system has been running so well that he uses it as an example of an ideal CO₂ booster system. Those who have visited the installation have even called him to rave about the rack and system performance. 

 

“It’s been running flawlessly and alarm-free. I tell my friends, ‘You need to come down here and see this.’ It’s something to behold,” Cole proudly exclaimed. 

 

 

CO2 refrigeration technologies

 

The installation and partnership with Zero Zone reflect Copeland’s longstanding commitment to developing user-friendly, robust and fully integrated CO₂ refrigeration technologies. As CO₂ installations like these become more commonplace throughout the country, Copeland will continue to adapt and develop innovative solutions to meet the demands of our industry, while simplifying the adoption of CO₂ refrigeration technologies for all stakeholders.

 

 

FAQs

What is a CO₂ transcritical booster system?

A CO₂ transcritical booster system is a refrigeration architecture that stages medium temperature (MT) and low temperature (LT) compressors together, using CO₂ as the refrigerant and operating in both subcritical and supercritical (transcritical) modes depending on ambient conditions.

 

Why do technicians monitor oil carry-over during CO₂ system start-up?

Oil carry-over affects compressor lubrication, so technicians monitor it closely during start-up, especially in supercritical mode, to reduce the risk of poor lubrication and compressor damage.

 

What role do Copeland compressor electronics play in CO₂ booster system troubleshooting?

Copeland compressor electronics provide performance data that helps technicians monitor compressor operation in real-time, making troubleshooting during commissioning faster and more straightforward.